8 800 250-3-111 многоканальный
Пн-Пт: с 9:00 до 18:00. Звонок по России бесплатный.

Wilo-Economy CO-1 Helix V.../EC

Your advantages Heavy-duty system which satisfies all the requirements of DIN 1988 (EN 806) High-efficiency pump hydraulics of the Helix V series in conjunction with IE3 IEC standard motors The spacer coupling enables the mechanical seal to be replaced without dismantling the motor (from 11 kW) Parts that come in contact with the fluid are corrosion-resistant The installed EC control device ensures easy adjustment and operationally reliability Factory testing and presetting to optimum working range Recommended services Maintenance Commissioning WiloCare

Артикул Наименование Цена
2554878 CO-1 Helix V 1611/K/EC Цена по запросу
2554859 CO-1 Helix V 1004/EC Цена по запросу
2554860 CO-1 Helix V 1005/EC Цена по запросу
2554861 CO-1 Helix V 1006/EC Цена по запросу
2554862 CO-1 Helix V 1007/EC Цена по запросу
2554863 CO-1 Helix V 1008/EC Цена по запросу
2554864 CO-1 Helix V 1009/EC Цена по запросу
2554865 CO-1 Helix V 1010/EC Цена по запросу
2554866 CO-1 Helix V 1011/EC Цена по запросу
2554867 CO-1 Helix V 1012/EC Цена по запросу
2554868 CO-1 Helix V 1013/EC Цена по запросу
2554869 CO-1 Helix V 1015/EC Цена по запросу
2554870 CO-1 Helix V 1603/EC Цена по запросу
2554871 CO-1 Helix V 1604/EC Цена по запросу
2554872 CO-1 Helix V 1605/EC Цена по запросу
2554873 CO-1 Helix V 1606/EC Цена по запросу
2554874 CO-1 Helix V 1607/EC Цена по запросу
2554875 CO-1 Helix V 1608/EC Цена по запросу
2554876 CO-1 Helix V 1609/K/EC Цена по запросу
2554877 CO-1 Helix V 1610/K/EC Цена по запросу
2554856 CO-1 Helix V 616/EC Цена по запросу
2554858 CO-1 Helix V 1003/EC Цена по запросу
2554857 CO-1 Helix V 1002/EC Цена по запросу
2554845 CO-1 Helix V 605/EC Цена по запросу
2554834 CO-1 Helix V 404/EC Цена по запросу

Design

High-efficiency, water-supply unit ready for connection. With vertical stainless steel high-pressure multistage centrifugal pump in glanded version, incl. EC controller (Easy Controller).

Application

  • Fully automatic water supply and pressure boosting in inlet mode, either from the public water supply network or from a tank, for domestic, commercial, industrial and municipal applications (e.g. residential, office, administration buildings, hotels, hospitals, trades, industry, water supply companies).
  • Pumping of drinking water and process water, cooling water, fire water (apart from fire-extinguishing systems in accordance with DIN 14462 and with the approval of the local fire safety authorities) or other types of industrial water that do not attack the materials either chemically or mechanically and do not contain abrasive or long-fibre constituents.

Equipment/function

  • 1 pump of the Helix V series with IE3 standard motor, including 0.75 kW and larger (optional for smaller motor power)
  • Components that come in contact with the fluid are corrosion-resistant
  • Base frame made of galvanised steel, with height-adjustable oscillation absorbers for insulation against structure-borne noise
  • Shut-off valve, discharge side
  • Non-return valve, discharge side
  • Diaphragm pressure vessel 8 l, PN 16, discharge side
  • Pressure transducer, discharge side
  • Pressure gauge, discharge side
  • Optionally with low-water cut-out switchgear (WMS) with pressure gauge, suction side
  • EC-control with IP54 plastic housing, consisting of an internal power supply unit, microprocessor, analogue and digital input and output modules

Typekey

Example:

Wilo-CO-1 Helix V 1608/K/EC

CO

Compact pressure-boosting system

1

Number of pumps

Helix V

Pump series

16

Rated volume flow [m3/h] of single pump

08

Number of single pump stages

K

With cartridge mechanical seal (for Helix V 22.., V 36.. and V 52..)

EC

Control unit; EC

Technical data

  • Mains connection 3~230/400 V +-10 %, 50 Hz (other versions on request)
  • Max. fluid temperature 50 °C (70 °C optional)
  • Max. ambient temperature of 40 °C
  • Operating pressure 16 bar
  • Inlet pressure 10 bar
  • Switching pressure ratings 6/10/16 bar
  • Nominal connection diameters on the discharge side Rp 1 1/4″ - DN 80
  • Nominal connection diameters on the inlet side (DN32) Rp 1 1/4" — DN 80
  • Rated speed 2850 rpm
  • Protection class IP54
  • Switching capacity P2 max. at max. 10 A = 4 kW (for > 4-kW downstream electromechanical power section)
  • Fuse protection on mains side AC 3 according to motor power and EVU regulations
  • Approved fluids (other fluids on request): Note regarding fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents.
    • Pure water without settling sediments
    • Process water, cold water, cooling water and rainwater
    • Drinking water
    • Firefighting water

Materials

Helix V 4 to V 16

  • Impellers, guide vanes, stage housing made of stainless steel 1.4307
  • Pump housing of stainless steel 1.4301
  • Shaft of stainless steel 1.4057
  • 1.4404 shaft protection sleeve
  • O-ring gaskets made of EPDM (FKM gasket on request)
  • Pipework made of 1.4571 stainless steel

Construction

  • Base frame: galvanised steel, with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
  • Pipework: complete pipework made of stainless steel, suitable for the connection of all piping materials used; the pipework is dimensioned according to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 pump of the Helix V 4 to Helix V 52 series; all parts which come into contact with the fluid are made of stainless steel; other versions on request. KTW/WRAS/ACS approval for all parts that come in contact with the fluid.
  • Valves: the pump is fitted on the pressure side with a shut-off device with DVGW approval mark or a shut-off valve with DVGW approval mark and on the pressure side with a KTW-approved non-return valve
  • Diaphragm pressure vessel: 8 l/PN 16 arranged on the discharge side with a diaphragm made of butyl rubber, with DVGW/KTW approval, completely safe in accordance with food safety laws, for testing and inspection purposes, with a shut-off ball cock with drain and throughflow fitting with DVGW/KTW approval in accordance with DIN 4807
  • Pressure sensor: 4 to 20 mA, arranged on the discharge side for controlling the central CE+ controller
  • Pressure indication: pressure gauge (ø 63 mm) arranged on the discharge side; additional digital indication of the discharge pressure on the alphanumeric touchscreen on the Comfort Controller
  • Control device/controller: the system is standard-equipped with a CE+ controller

Scope of delivery

  • Factory-mounted, ready for connection pressure boosting system checked for functionality and impermeability
  • Installation and operating instructions

Typekey

Example:

Wilo-CO-1 Helix V 1608/K/EC

CO

Compact pressure-boosting system

1

Number of pumps

Helix V

Pump series

16

Rated volume flow [m3/h] of single pump

08

Number of single pump stages

K

With cartridge mechanical seal (for Helix V 22.., V 36.. and V 52..)

EC

Control unit; EC

Technical data

  • Mains connection 3~230/400 V +-10 %, 50 Hz (other versions on request)
  • Max. fluid temperature 50 °C (70 °C optional)
  • Max. ambient temperature of 40 °C
  • Operating pressure 16 bar
  • Inlet pressure 10 bar
  • Switching pressure ratings 6/10/16 bar
  • Nominal connection diameters on the discharge side Rp 1 1/4″ - DN 80
  • Nominal connection diameters on the inlet side (DN32) Rp 1 1/4" — DN 80
  • Rated speed 2850 rpm
  • Protection class IP54
  • Switching capacity P2 max. at max. 10 A = 4 kW (for > 4-kW downstream electromechanical power section)
  • Fuse protection on mains side AC 3 according to motor power and EVU regulations
  • Approved fluids (other fluids on request): Note regarding fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents.
    • Pure water without settling sediments
    • Process water, cold water, cooling water and rainwater
    • Drinking water
    • Firefighting water

Materials

Helix V 4 to V 16

  • Impellers, guide vanes, stage housing made of stainless steel 1.4307
  • Pump housing of stainless steel 1.4301
  • Shaft of stainless steel 1.4057
  • 1.4404 shaft protection sleeve
  • O-ring gaskets made of EPDM (FKM gasket on request)
  • Pipework made of 1.4571 stainless steel

Construction

  • Base frame: galvanised steel, with height-adjustable vibration absorbers for comprehensive insulation against structure-borne noise; other versions on request
  • Pipework: complete pipework made of stainless steel, suitable for the connection of all piping materials used; the pipework is dimensioned according to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 pump of the Helix V 4 to Helix V 52 series; all parts which come into contact with the fluid are made of stainless steel; other versions on request. KTW/WRAS/ACS approval for all parts that come in contact with the fluid.
  • Valves: the pump is fitted on the pressure side with a shut-off device with DVGW approval mark or a shut-off valve with DVGW approval mark and on the pressure side with a KTW-approved non-return valve
  • Diaphragm pressure vessel: 8 l/PN 16 arranged on the discharge side with a diaphragm made of butyl rubber, with DVGW/KTW approval, completely safe in accordance with food safety laws, for testing and inspection purposes, with a shut-off ball cock with drain and throughflow fitting with DVGW/KTW approval in accordance with DIN 4807
  • Pressure sensor: 4 to 20 mA, arranged on the discharge side for controlling the central CE+ controller
  • Pressure indication: pressure gauge (ø 63 mm) arranged on the discharge side; additional digital indication of the discharge pressure on the alphanumeric touchscreen on the Comfort Controller
  • Control device/controller: the system is standard-equipped with a CE+ controller

Scope of delivery

  • Factory-mounted, ready for connection pressure boosting system checked for functionality and impermeability
  • Installation and operating instructions